Last data update: May 06, 2024. (Total: 46732 publications since 2009)
Records 1-11 (of 11 Records) |
Query Trace: Yantek DS[original query] |
---|
Cryogenic air supply feasibility for a confined space: Underground refuge alternative case study
Yan L , Yantek DS , DeGennaro CR , Srednicki JR , Lambie B , Carr J . ASME J Heat Mass Transf 2024 146 (3) A breathable air source is required for a confined space such as an underground refuge alternative (RA) when it is occupied. To minimize the risk of suffocation, federal regulations require that mechanisms be provided and procedures be included so that, within the refuge alternative, the oxygen concentration is maintained at levels between 18.5% and 23% for 96 h. The regulation also requires that, during use of the RA, the concentration of carbon dioxide should not exceed 1%, and the concentration of carbon monoxide should not exceed 25 ppm. The National Institute for Occupational Safety and Health (NIOSH) evaluated the cryogenic air supply's ability to provide breathable air for a refuge alternative. A propane smoker was used to simulate human breathing by burning propane gas which will consume O(2) and generate CO(2) and H(2)O. The rate of propane burned at the smoker was controlled to represent the O(2) consumption rate for the breathing of a certain number of people. Two 96-h tests were conducted in a sealed shipping container, which was used as a surrogate for a refuge alternative. While burning propane gas to simulate human oxygen consumption, cryogenic air was provided to the shipping container to determine if the cryogenic air supply would keep the O(2) level above 18.5% and CO(2) level below 1% inside the shipping container as required by the federal regulations pertaining to refuge alternatives. Both of the 96-h tests simulated the breathing of 21 persons. The first test used the oxygen consumption rate (1.32 cu ft of pure oxygen per hour per person) specified in federal regulations, while the second test used the oxygen consumption rate specified by (Bernard et al. 2018, "Estimation of Metabolic Heat Input for Refuge Alternative Thermal Testing and Simulation," Min. Eng., 70(8), pp. 50-54) (0.67 cu ft of pure oxygen per hour per person). The test data shows that during both 96-h tests, the oxygen level was maintained within a 21-23% range, and the CO(2) level was maintained below 1% (0.2-0.45%). The information in this paper could be useful when applying a cryogenic air supply as a breathable air source for an underground refuge alternative or other confined space. [DOI: 10.1115/1.4064062]. |
Evaluation of a prototype local ventilation system to mitigate retail store worker exposures to airborne particles
Lee T , Barone T , Yantek DS , Portnoff L , Zheng Y . J Occup Environ Hyg 2023 20 (7) 1-22 The objective of this study is to evaluate a prototype local ventilation system (LVS) intended to reduce retail store workers' exposures to aerosols. The evaluation was carried out in a large aerosol test chamber where relatively uniform concentrations of polydisperse sodium chloride and glass-sphere particles were generated to test the system with nano- and micro-size particles. In addition, a cough simulator was constructed to mimic aerosols released by mouth breathing and coughing. Particle reduction efficiencies of the LVS were determined in four different experimental conditions using direct reading instruments and inhalable samplers. The particle reduction efficiency (%) depended on the position beneath the LVS, but the percentage was consistently high at the LVS center as follows: 1) > 98% particle reduction relative to background aerosols, 2) > 97% in the manikin's breathing zone relative to background aerosols, 3) > 97% during mouth breathing and coughing simulation, and 4) > 97% with a plexiglass barrier installation. Lower particle reduction (<70%) was observed when the LVS airflow was disturbed by background ventilation airflow. The lowest particle reduction (<20%) was observed when the manikin was closest to the simulator during coughing. |
Mathematical modeling for carbon dioxide level within confined spaces
Yan L , Yantek DS , DeGennaro CR , Fernando RD . ASCE ASME J Risk Uncertain Eng Syst Part B Mech Eng 2023 9 (2) Federal regulations require refuge alternatives (RAs) in underground coal mines to provide a life-sustaining environment for miners trapped underground when escape is impossible. A breathable air supply is among those requirements. For built-in-place (BIP) RAs, a borehole air supply (BAS) is commonly used to supply fresh air from the surface. Federal regulations require that such a BAS must supply fresh air at 12.5 cfm or more per person to maintain the oxygen concentration between 18.5% and 23% and carbon dioxide level below the 1% limit specified. However, it is unclear whether 12.5 cfm is indeed needed to maintain this carbon dioxide level. The minimal fresh air flow (FAF) rate needed to maintain the 1% CO2level will depend on multiple factors, including the number of people and the volume of the BIP RA. In the past, to predict the interior CO2concentration in an occupied RA, 96-h tests were performed using a physical human breathing simulator. However, given the infinite possibility of the combinations (number of people, size of the BIP RA), it would be impractical to fully investigate the range of parameters that can affect the CO2concentration using physical tests. In this paper, researchers at the National Institute for Occupational Safety and Health (NIOSH) developed a model that can predict how the %CO2in an occupied confined space changes with time given the number of occupants and the FAF rate. The model was then compared to and validated with test data. The benchmarked model can be used to predict the %CO2for any number of people and FAF rate without conducting a 96-h test. The methodology used in this model can also be used to estimate other gas levels within a confined space. © 2023 American Society of Mechanical Engineers (ASME). All rights reserved. |
Underground mine air and strata temperature change due to the use of refuge alternatives
Yan L , Yantek DS , Reyes MA . Min Metall Explor 2019 37 (2) [Epub ahead of print] Heat and humidity buildup withn refuge alternatives (RAs) may expose occupants to physiological hazards such as heat stress. The Mine Safety and Health Administration (MSHA) regulations require RAs in underground coal mines to provide a life-sustaining environment for miners trapped underground when escape is impossible. RAs are required to sustain life for 96 h while maintaining an apparent temperature (AT) below 95 degrees F (35 degrees C). The National Institute for Occupational Safety and Health (NIOSH) tested a 10-person tent-type RA, a 23-person tent-type RA, and a 6-person metal-type RA in its underground coal mine facilities to investigate the thermal environment over a 96-h period. The test results showed that mine air and mine strata temperatures surrounding an RA occupied by simulated miners (SMs) increased over the 96-h test period. The test results suggest that RA manufacturers should consider this increase in temperatures when calculating and evaluating RA components during surface and laboratory tests. The findings can equip stakeholders with additional considerations for calculating the interior heat and humidity temperature profiles for occupied RAs not tested in situ. |
A test method for evaluating the thermal environment of underground coal mine refuge alternatives
Yantek DS , Yan L , Damiano NW , Reyes MA , Srednicki JR . Int J Min Sci Technol 2019 29 (3) 343-355 Since 2009, the Mine Safety and Health Administration (MSHA) has required mines to install refuge alternatives (RAs) in underground coal mines. One of the biggest concerns with occupied RAs is the possible severity of the resulting thermal environment. In 30 CFR 7.504, the maximum allowable apparent temperature (AT) for an occupied RA is specified as 35 °C (95 °F). Manufacturers must conduct heat/humidity tests to demonstrate that their RAs meet the 35 °C (95 °F) AT limit. For these tests, heat input devices are used to input the metabolic heat of actual miners. A wide variety of test methods, sensors, and heat input devices could be used when conducting such tests. Since 2012, the National Institute for Occupational Safety and Health (NIOSH) has conducted over thirty 96-hour heat/humidity tests on four different RAs. This paper discusses the test equipment and procedures used during these investigations. This information is useful for RA manufacturers conducting RA heat/humidity tests, for other researchers investigating RA heat/humidity buildup, and for those who need to assess the thermal environment of any confined space where people may be trapped or are seeking refuge. |
Estimation of metabolic heat input for refuge alternative thermal testing and simulation
Bernard TE , Yantek DS , Thimons ED . Min Eng 2018 70 (8) 50-54 Refuge alternatives provide shelter to miners trapped underground during a disaster. Manufacturers must demonstrate that their refuge alternatives meet the U.S. Mine Safety and Health Administration (MSHA) requirements for oxygen supply, carbon dioxide removal, and management of heat from the occupants and mechanical/chemical systems. In this study, miner size and activity level were used to determine the metabolic heat rate, oxygen requirements and carbon dioxide generation that are representative of miners in a refuge situation. A convenience sample of 198 male miners was used for the distribution of current U.S. coal miners, and the composite 95th percentile height and weight were determined to be 193 cm (76 in.) and 133 kg (293 lb). The resting metabolic rate (RMR) was determined to be representative of activity level in a refuge alternative. The highest likely metabolic heat generation ranged from 113 to 134 W, depending on occupancy. The highest required oxygen supply and carbon dioxide removal were estimated to be 23 L (0.81 cu ft) of oxygen per hour per person and 20 L (0.71 cu ft) of carbon dioxide per hour per person, which means the margin of safety is 50 percent or more compared with the MSHA requirements. The information on metabolic heat generation can be used to assess refuge alternative thermal environments by testing or simulation. The required oxygen supply and carbon dioxide removal can be used to assess refuge alternative requirements. |
Prediction of human core temperature rise and moisture loss in refuge alternatives for underground coal mines
Klein M , Yantek DS , Hepokoski M , Yan L . Trans Soc Min Metall Explor Inc 2017 342 29-35 Research by the U.S. National Institute for Occupational Safety and Health (NIOSH) has shown that heat/humidity buildup is a major concern within coal mine refuge alternatives. High temperature and humidity levels inside a refuge alternative may expose occupants to heat stress. Due to the safety risks associated with testing using human subjects, NIOSH partnered with ThermoAnalytics Inc. to create detailed thermal simulation models of refuge alternatives with human occupants. The objective of this effort was to predict a miner's core temperature response and moisture loss in environments that may be encountered in a coal mine refuge alternative. These parameters were studied across a range of temperatures and relative humidity values to determine if the current 35 °C (95 °F) apparent temperature limit for refuge alternatives is reasonable. The results indicate that the apparent temperature limit is protective, provided that miners are supplied with sufficient water. The results also indicate that the body core temperature does not reach dangerous levels even at an apparent temperature of 54 °C (130 °F). However, the results show that moisture loss increases with apparent temperature. Therefore, if the apparent temperature limit were raised, the water provided in a refuge alternative would have to be increased to offset moisture loss. |
Effects of mine strata thermal behavior and mine initial temperatures on mobile refuge alternative temperature
Yantek DS , Yan L , Bissert PT , Klein MD . Min Eng 2017 69 (4) 41-48 Federal regulations require the installation of refuge alternatives (RAs) in underground coal mines. Mobile RAs have a limited ability to dissipate heat, and heat buildup can lead to a life-threatening condition as the RA internal air temperature and relative humidity increase. The U.S. National Institute for Occupational Safety and Health (NIOSH) performed heat testing on a 10-person tent-type training RA and contracted ThermoAnalytics Inc. to develop a validated thermal simulation model of the tested RA. The model was used to examine the effects of the constant mine strata temperature assumption, initial mine air temperature, initial mine strata surface temperature (MSST), initial mine strata temperature at depth (MSTD) and mine strata thermal behavior on RA internal air temperature using 117 W (400 Btu/h) of sensible heat input per simulated miner. For the studied RA, when the mine strata temperature was treated as a constant, the final predicted RA internal air temperature was 7.1 C (12.8 F) lower than it was when the mine strata thermal behavior was included in the model. A 5.6 C (10 F) increase in the initial MSST resulted in a 3.9 C (7.1 F) increase in the final RA internal air temperature, whereas a 5.6 C (10 F) increase in the initial MSTD yielded a 1.4 C (2.5 F) increase in the final RA internal air temperature. The results indicate that mine strata temperature increases and mine strata initial temperatures must be accounted for in the physical testing or thermal simulations of RAs. |
Analysis of heat loss mechanisms for mobile tent-type refuge alternatives
Bissert PT , Yantek DS , Klein MD , Yan L . Trans Soc Min Metall Explor Inc 2016 340 (1) 70-74 Federal regulations require that refuge alternatives (RAs) be located within 305 m (1,000 ft) of the working face and spaced at one-hour travel distances in the outby area in underground coal mines, in the event that miners cannot escape during a disaster. The Mine Safety and Health Administration mandates that RAs provide safe shelter and livable conditions for a minimum of 96 hours while maintaining the apparent temperature below 35 °C (95 °F). The U.S. National Institute for Occupational Safety and Health used a validated thermal simulation model to examine the mechanisms of heat loss from an RA to the ambient mine and the effect of mine strata composition on the final internal dry bulb temperature (DBT) for a mobile tent-type RA. The results of these studies show that 51 percent of the heat loss from the RA to the ambient mine is due to radiation and 31 percent to conduction. Three mine width and height configurations and four mine strata compositions were examined. The final DBT inside the RA after 96 hours varied by less than 1 °C (1.8 °F) for the three mine width/height configurations and by less than 2 °C (3.6 °F) for the four mine strata compositions. |
Evaluations of a noise control for roof bolting machines
Azman AS , Yantek DS , Alcorn lA . Min Eng 2012 64 (12) 64-70 In collaboration with Kennametal Inc. and Corry Rubber Corporation, the U.S. National Institute for Occupational Safety and Health (NIOSH) developed a drill bit isolator to address noise overexposures associated with roof bolting machines in underground coal mines. NIOSH laboratory studies confirmed that the drill bit isolator reduces noise during drilling. Field studies were needed to confirm that a noise reduction could be obtained under working conditions and that the device was sufficiently durable. This paper reports results of field tests of the device conducted at five underground coal mines. Noise reduction was assessed by comparing the operator’s noise exposure during drilling with and without the drill bit isolator. Durability was assessed by recording the number of holes and total feet drilled with each bit isolator until either the test period ended or the device failed. The results from these tests showed that the device is an effective noise control in a mine environment. The field-tested drill bit isolators provided a noise reduction of 3-5 dB(A). Of nine devices tested for durability, five exceeded 610 m (2,000 ft) drilled and two exceeded 762 m (2,500 ft) drilled before failure. Durability issues found in the field tests led to final production optimizations that have resulted in a commercially available product for drilling with 35-mm- (1.3-in.-) diameter roof bits and hexagonal drill steels. |
Analysis of a mechanism suspension to reduce noise from horizontal vibrating screens
Yantek DS , Lowe MJ . Noise Control Eng J 2011 59 (6) 568-580 A-weighted sound levels around vibrating screens in coal preparation plants often exceed 90 dB. The National Institute for Occupational Safety and Health (NIOSH) is developing noise controls to reduce noise generated by horizontal vibrating screens. Horizontal vibrating screen noise is dominated by sound radiated from the screen body. NIOSH researchers analyzed a mechanism suspension system that could reduce screen body-radiated noise. A finite element (FE) model of the entire screen was used to analyze the screen with the added mechanism suspension. The spring rates for the mechanism suspension were tuned to transmit vibration at the mechanism operating speed while attenuating vibration transmitted from the mechanisms to the screen body at frequencies above 100 Hz. The FE results were used to estimate the A-weighted sound power level radiated by the screen sides and feedbox for various mechanism suspension spring rates. The results indicate that a tuned mechanism suspension could reduce the A-weighted sound power level radiated by the screen body due to gear and bearing forces inside the mechanisms by 7 to 18 dB. |
- Page last reviewed:Feb 1, 2024
- Page last updated:May 06, 2024
- Content source: